tTEM data acquisition: the transmitter and receiver antennas are towed behind an ATV. Photo: WSP Danmark
Danish EPA: tTEM improved every risk assessment tested
A new report from the Danish Environmental Protection Agency tested tTEM at eight contaminated sites across four Danish regions. In every case, the survey gave a better, more robust risk assessment, and in two cases it meant remediation or monitoring could be avoided.
When a contaminated site threatens drinking water, the key question is underground: is there a clay layer protecting the aquifer, and is it continuous? Answering that has usually meant drilling – one borehole at a time, at high cost.
A report published in July 2026 by the Danish Environmental Protection Agency (Miljøstyrelsen) shows what changes when you scan the ground first. The project, Environmental Project No. 2315, was carried out by WSP Danmark and Region Midtjylland with Region Nordjylland, Region Syddanmark and Region Hovedstaden. It tested tTEM at eight contaminated sites, including former landfills, farms, machine stations and factories.
一览
- 8 of 8 sites with an improved risk assessment
- 2 cases where remediation or monitoring was avoided
- DKK 310,000 (€42,000) of deep boreholes at Voldum that tTEM would have made unnecessary, against a DKK 60,000–75,000 (€8,000–10,000) survey
- 6 of 8 cases where tTEM should have been used earlier
What tTEM does
tTEM is a towed geophysical scanner pulled behind an ATV. It maps the electrical resistivity of the upper 50–70 metres of the subsurface along lines 10–25 metres apart, covering 100–140 hectares a day. The result is a 3D picture of clay layers, sand layers, buried valleys and faults – the structures that decide where contamination can travel. The system was developed at Aarhus University and is now developed and manufactured by TEMcompany.
What the report found
- Better risk assessments in all eight cases. Mapping clay layers and the gaps in them gave case officers more certainty about flow paths.
- Remediation or monitoring avoided in two cases because the survey showed the aquifer was protected.
- Fewer boreholes. At Voldum, seven deep boreholes costing about DKK 310,000 (€42,000) would have been unnecessary had tTEM come first; a survey of that size costs DKK 60,000–75,000 (€8,000–10,000).
- Shorter cases. At Stampevej, scanning before the main investigation saved at least one investigation phase and around DKK 300,000 (€40,000) in boreholes, for a survey cost of about DKK 67,000 (€9,000).
- Earlier is better. In six of eight cases, the authors conclude tTEM should have been used earlier in the process.
- Lower environmental impact. tTEM is non-invasive, so it avoids the risk drilling carries of opening a path between aquifers.
Cost-benefit findings
The report’s cost-benefit assessments conclude that tTEM almost always makes economic sense: saving just a few deep boreholes pays for a survey.
| Site | Drilling avoided or avoidable | Cost of drilling | Cost of tTEM survey |
|---|---|---|---|
| Stampevej, Ringkøbing | At least 4 deep boreholes (30–35 m) avoided, as tTEM was used before the main investigation | About DKK 300,000 (€40,000) |
About DKK 67,000 (€9,000) |
| Voldum | 7 deep boreholes that would have been unnecessary had tTEM come first | About DKK 310,000 (€42,000) |
DKK 60,000–75,000 (€8,000–10,000) |
At Stampevej, the authors note that even four boreholes would not have explained the area’s geology, and that the survey was a good investment both financially and in quality.
At Rygesmindevej in Them, the authors conclude it would have paid to run tTEM as one of the first steps. Understanding how the contamination spreads earlier would have allowed a more cost- and environmentally-efficient investigation.
At Skovlytoften in Søllerød, tTEM mapped the geology over a large area – including beneath Søllerød Sø – for a limited outlay. Used earlier, it would have pointed to the groundwater pressure conditions that matter most for the risk assessment, and given a more nuanced assessment for the lake.
The eight sites
| Site | 地区 | 污染 | What tTEM showed |
|---|---|---|---|
| Hanehøjvej, Skørping | Nordjylland | Former landfills, pesticides | No continuous clay layer under the landfills; two follow-up boreholes confirmed it |
| Voldum | Midtjylland | Machine station, pesticides | Palaeocene clay layer protects the nearby wellfield; flow runs away from it |
| Stampevej, Ringkøbing | Midtjylland | Fill site, PFAS and pesticides | Existing regional models were too coarse; one deep borehole replaced at least four |
| Rygesmindevej, Them | Midtjylland | Factory, chlorinated solvents | Buried valleys under tunnel valleys and a deep Miocene clay layer |
| Skovmølleværket, Svendborg | Syddanmark | Wellfield, DMS (pesticide residue) | A buried valley 200 m from the affected well connects shallow and deep aquifers |
| Vesterlund Landfill, Als | Syddanmark | Former landfill, chlorinated solvents | A clay barrier keeps contamination under the site; earlier use would have saved at least DKK 200,000 (€27,000) |
| Nybølle | Hovedstaden | Farm, pesticides | Very thin cover over the limestone aquifer east of the site, pointing to diffuse field sources |
| Skovlytoften, Søllerød | Hovedstaden | Factory, TCE | Clay layer over the limestone, cut by a tunnel valley; mapped on land and on the lake (floaTEM) |
Where it fits – and where it doesn't
The report is clear about limits. tTEM is sensitive to power lines, cables, fences and large metal objects, and generally needs to stay 30–50 metres from them. That rules out dense urban sites. Even so, at two sites in scattered urban development, data collected in the surroundings still gave useful input to the case.
What the report recommends
- Use tTEM early – ideally before the further investigation – so the conceptual model guides where boreholes go.
- Survey a wide enough area, typically more than 100–150 hectares, so geological structures can be seen whole.
- Keep line spacing to 20 metres or less and driving speed to about 15 km/h where detail matters.
- Bring the geophysicist, geologist and case officer together in workshops, and revisit the data as new questions arise.
The report comes with a separate guidance document on using tTEM in contamination cases (Edsen, Okholm & Jørgensen, 2026).
Read the report
The full report is published in Danish by Miljøstyrelsen. To make it accessible to international readers, we have also prepared an English version.
- Original report in Danish (PDF, Miljøstyrelsen) – the authoritative version
- Unofficial English translation (PDF, 6 MB)
Please note: The English version is an unofficial machine translation prepared by TEMcompany. It has not been reviewed or approved by Miljøstyrelsen, the report’s authors or the project partners. The Danish edition is the authoritative version, and in case of any discrepancy the Danish text applies. Please cite the Danish original.
Frequently asked questions
What is tTEM?
tTEM (towed transient electromagnetic) is a geophysical scanner towed behind an ATV. It maps the electrical resistivity of the upper 50–70 metres of the subsurface, covering 100–140 hectares a day, and shows clay layers, sand layers, buried valleys and faults in 3D.
What did the Danish EPA report find about tTEM?
Miljøstyrelsen’s Environmental Project No. 2315 tested tTEM at eight contaminated sites in four Danish regions. The risk assessment improved at all eight sites, remediation or monitoring was avoided in two cases, and in six of eight cases the authors conclude tTEM should have been used earlier.
How much does a tTEM survey cost compared with drilling?
At Voldum, a tTEM survey costing DKK 60,000–75,000 (€8,000–10,000) would have made seven deep boreholes worth about DKK 310,000 (€42,000) unnecessary. At Stampevej, a survey of about DKK 67,000 (€9,000) saved around DKK 300,000 (€40,000) in boreholes.
When should tTEM be used in a contaminated-site investigation?
Early – ideally before the further investigation – so the geological model can guide where boreholes go. The report recommends surveying more than 100–150 hectares with line spacing of 20 metres or less.
Where can tTEM not be used?
tTEM needs to stay 30–50 metres from power lines, cables, fences and large metal objects, so it is not suited to dense urban sites. Data from the surrounding area can still help on sites with scattered development.
Planning a contaminated-site investigation? Talk to us about how tTEM can map the subsurface before you drill. Read more on our tTEM family page, or read the full report in Danish or in our unofficial English translation.
The project was funded by the Danish EPA’s Technology Development Programme for Soil and Groundwater Contamination, co-funded by the participating regions and WSP, and carried out by WSP Danmark and Region Midtjylland, with Region Nordjylland, Region Syddanmark and Region Hovedstaden. Geoscience at Aarhus University and the Knowledge Centre for Environment and Resources (VMR), Danish Regions, took part in project meetings. Report editors: Flemming Jørgensen (Region Midtjylland) and Anders Edsen (WSP Danmark).
Citation: Miljøstyrelsen (2026). “tTEM – ny kortlægningsmetode til risikovurdering af grundvandsforurening fra punktkilder” [tTEM – a new mapping method for risk assessment of groundwater contamination from point sources]. Edited by Flemming Jørgensen (Region Midtjylland) and Anders Edsen (WSP Danmark). Miljøprojekt nr. 2315, July 2026. Odense: Danish Environmental Protection Agency. ISBN 978-87-7564-126-0. Available at: www2.mst.dk/Udgiv/publikationer/2026/07/978-87-7564-126-0.pdf
The English translation linked on this page is unofficial and provided for convenience only. All rights in the original report remain with Miljøstyrelsen and the authors.
Euro amounts are approximate, converted at DKK 7.46 = €1 and rounded to the nearest €1,000.


